Hi,
Can you assist?
In your datasheet you have one value per embedment depth for hmin minimum base material thickness.
Your ETA document has one value of hmin which is given as h1+30mm, however h1 can be different.
e.g. for a HUS14 with hom3 h is noted as 200mm.
h1 for cleaned hole = 125mm, h = h1+30=155mm
h1 uncleaned flo...